Fetal Monitor


Star 5000 Fetal Monitor
Send Enquiry

Price : INR 95,000.00 / Piece(s)

Product Details

Application Hospital
Condition New
Color Multi
Automation Grade Automatic

Features

  • FoIdable handle S portable, all-in-one probe holder.
  • Display: 12.1 inch foldable color TFT LCD screen, a Calculation and display of auto/manual fetal movement, st The color of parameters and waveforms settable as per user' s preference.
  • At least 24 hours CTG data storage, selectable review and print after power off.
  • 25mm/s high speed printing of stored CTG data.
  • Print-speed Selectable;
  • 1cm/min, 2cm/min, 3cm/min, 25mm/sec Alarm reviewable.
  • Auto/manual patient ID generation,
  • easy user-management & data
  • Audio and visual alarm,
  • lightness and volume are adjustable.
  • Alarm S remark are available for probe moving and abnormal condition.
  • America and international 2 Standards print function.
  • Display/offset print of Twins FHR (fetal heart r...

Read More...


Yes! I am interested


Product Details

Application Hospital Use
Screen Size 12inch
Frequency 50HZ, 60HZ
Memory Size 256mb
Warranty 1year
brand G6B

Technical Details

FHR
Ultrasound frequency 1 Mhz±1KHz
Ultrasound input intensity <10MW/cm2
Range 30~240bpm
Accuracy ±1bpm
Alarm limit & Tolrance Max (32~240)bpm, tolrance : ±5%)
TOCO
Measurement Range 0~100%
Resolution 0.01
Pressure tolrance 0.07
Zero-mode Manual and Automatic
Fetal Movement
Count mode Automatic and Manual
Automatic fetal movement waveform
ECG
Input 3 wires/5 wires ECG cable
Lead section I, II, III, aVR, aVL, aVF, V
Gain selection X1/4, x1/2, x1, x2, x4 and automatic
Sweep Speed 6.25, 12.5, 25, 50mm/s
Heart rate range 15~380bpm
Callibration 1mv
SpO2
Display Type Waveform, data
Measurement Range 0~100%
Accuracy 0.02
Pulse rate range 30~250bpm
Accuracy 1bpm
NIBP
Philosophy Oscillometric method
Measurement type Adult, pediatric, nenonate
Measurement parameter Systiolic, diastolic, Mean
Measurement method Manual , automatic, continuous measurement
Unit mmHg/kPa selectable
Accuracy 2 or 3mmHg
Respiration
Thoracic impedance & nasal tube double method selectable  
Measurement Range 0~120bpm
Accuracy ±1bpm
Resolution 1bpm
Temperature
Number of channel 2 channels
Resolution 0.1C
Display T1, T2, Delta T
Wide Line Printer
Printing paper Foldable Z-type thermal paper
Width 150mm
Sweep Speed 1,2, 3cm/min, 25mm/sec
Power Requirement 100~240VAC, 50/60hz

Horizontal type, portbale & compact. Advanced steamline outline design. It can real-time monitor the changes of physical signs of the fetal and maternal. It was designed in compliance with different requirement of antenatal, childbirth and postpatum patients. Comply with chinese & international standard.

 

Features :

  • Foldable handle & portable, all-in-one probe holder.
  • 12.1 inch foldable color TFT LCD screen. It can diplay waveform and data simultaneously.
  • With function of FHR, TOCO, FM and activities curve of fetal
  • Calculation of auto/manual movement
  • Color of interface is adjustable.
  • At least 24 hours CTG data stroage, review of printing is available, the data can be saved after power off.
  • Alarm review.
  • Auto/manual patient ID generation, easy user-management &am...

Read More...


Yes! I am interested



Looking for Product Name ?